{"product_id":"osburn-caddy-advanced-wood-furnace-pf01020","title":"Osburn Caddy Advanced Wood Furnace PF01020","description":"\u003ch2\u003eOsburn Caddy Advanced Wood Furnace PF01020\u003c\/h2\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e\n\u003cstrong\u003e1,000 - 2,500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFt\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd data-spec-id=\"DimExHLi,DimExHPi,DimExHHi\"\u003e\n\u003cstrong\u003e28 3\/4\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eW X\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e42 1\/2\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eD X\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e41 3\/4\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd data-spec-id=\"LongBuci\"\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage particulate emissions rate\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-1\" data-target-tab=\"specification-documentation\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\"\u003e\u003cstrong\u003e0.09 lb\/mmBTU (0.039 g\/MJ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage electrical power consumption\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-2\" data-target-tab=\"specification-documentation\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ConsElec\"\u003e\u003cstrong\u003e220 W | 360 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage CO\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-3\" data-target-tab=\"specification-documentation\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\"\u003e\u003cstrong\u003e1.3 g\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eTHE NEW GENERATION OF FURNACES\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eKnown for its exceptional performance, the Caddy Advanced is a furnace that’s innovative design (patent pending) is surpassed only by its simplicity of use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDISCOVER SELF-REGULATED COMBUSTION\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe self-regulated combustion of the Caddy Advanced promises constant heat, while requiring minimal effort on your part; just fill the furnace, adjust the temperature and enjoy the heat for hours! The system automatically adjusts the air supply so that combustion is optimized and synchronized with the thermostatic demand.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt start-up, the furnace injects additional combustion air for easy and quick ignition.\u003c\/li\u003e\n\u003cli\u003eAs the furnace goes into heating mode, it automatically adjusts the combustion air supply and the operation of the convection blower. When your home’s desired temperature is reached (thermostat setting), the furnace goes into energy saving mode, automatically reducing the combustion air and speed of the convection blower.\u003c\/li\u003e\n\u003cli\u003eAt the end of the combustion cycle, if the furnace needs to go back to heating mode (thermostat setting), additional combustion air is injected again to activate the combustion of the embers thus providing a hotter burn on the end of the combustion cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEASE OF USE\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the Caddy Advanced with confidence thanks to its intuitive operation and illustrated quick user guide. Equipped with a glass door allowing you to easily monitor the state of combustion, the furnace optimizes its combustion cycle: you will spend much less time taking care of it vs a conventional furnace (loading wood, adjusting the air, etc.). This optimization also ensures you substantial savings in firewood as well as increased comfort thanks to the production of constant heat throughout the combustion cycle.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eUNMATCHED PERFORMANCE\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAmong the most efficient furnaces in terms of energy distribution, the Caddy Advanced has one of the lowest minimum burn rates in the industry. This means a load of wood burns longer, and therefore reduces the frequency of wood loading. Emissions on this unit are amongst the cleanest of the few EPA 2020 certified furnaces, and yet the Caddy Advanced is among the most energy efficient on the market. In addition, the new ECM motor blower option consumes 40% less electricity (and much quieter) than a standard PSC motor blower.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQUICK AND FLEXIBLE INSTALLATION\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Caddy Advanced is equipped with pre-wired electrical components that allow for simplified and intuitive connection. For more flexibility, you can install the filter supports on either sides and on top of the blower box to adapt the layout of the ventilation ducts to your space. In addition, the add-on configuration allows you to install the Caddy Advanced with your existing electric, oil or gas central heating system to take advantage of an alternative energy source.\u003c\/p\u003e\n\u003cp\u003eThe Caddy Advanced includes a tool set and wall support, an ash lip, a thermostat, a moisture reader, a barometric damper and a fresh air intake adapter.\u003c\/p\u003e\n\u003ch3\u003eALTERNATE SOURCE OF HEAT\u003c\/h3\u003e\n\u003cp\u003eAlways have an alternate source of heat to ensure the comfort and safety of your family. The Caddy\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAdvanced \u003c\/span\u003ecomes in two different configurations: wood-only and wood add-on furnace.\u003c\/p\u003e\n\u003cp\u003eWhen installed as an add-on furnace, only a series configuration is approved for Canada. In the United States, both series and parallel configuration are permitted.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAPPLIANCE PERFORMANCE\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-4\" data-target-tab=\"specification-documentation\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel type\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003e\u003cstrong\u003eDry cordwood (16\" recommended)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area-ft²\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#recommended-maximum\" data-target-tab=\"specification-documentation\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e\u003cstrong\u003e1,000 - 2,500\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall firebox volume-ft³\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e\u003cstrong\u003e3.6\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#recommended-maximum\" data-target-tab=\"specification-documentation\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e\u003cstrong\u003e10 h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input capacity (dry cordwood)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-6\" data-target-tab=\"specification-documentation\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"CapCordi\" colspan=\"2\"\u003e\u003cstrong\u003e310,000 BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall heat output rate \u0026lt;\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-7\" data-target-tab=\"specification-documentation\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e\n\u003cstrong\u003e21,742 BTU\/h (6.37 kW)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e62,107 BTU\/h (18.2 kW)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-8\" data-target-tab=\"specification-documentation\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMMin\" colspan=\"2\"\u003e\n\u003cstrong\u003e78 %\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivered heat output rate (min. to max.)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-10\" data-target-tab=\"specification-documentation\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThDMin,PwThDMax\" colspan=\"2\"\u003e\n\u003cstrong\u003e19,851 BTU\/h (5.82 kW)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e64,073 BTU\/h (18.8 kW)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage delivered efficiency\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-11\" data-target-tab=\"specification-documentation\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMDMin\" colspan=\"2\"\u003e\n\u003cstrong\u003e77 %\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum efficiency\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-12\" data-target-tab=\"specification-documentation\"\u003e11\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e\u003cstrong\u003e79 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage particulate emissions rate\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-1\" data-target-tab=\"specification-documentation\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-13\" data-target-tab=\"specification-documentation\"\u003e12\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e\u003cstrong\u003e0.09 lb\/mmBTU (0.039 g\/MJ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage CO\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-3\" data-target-tab=\"specification-documentation\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e\u003cstrong\u003e1.3 g\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage electrical power consumption\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.caddyfurnaces.com\/en\/products\/caddy-advanced-ii-wood-furnace\/#note-order-2\" data-target-tab=\"specification-documentation\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ConsElec\" colspan=\"2\"\u003e\u003cstrong\u003e220 W | 360 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eBased on delivered heat output.\u003c\/p\u003e\n\u003cp id=\"note-order-2\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eUnless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at minimum 10 lb\/ft³ and with a moisture content between 18% and 28%.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eInput value at 10 lb\/ft³ fuel loading density and dry energy value of 8,600 BTU\/lb.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOverall : Radiated and delivered heat together at 10 lb\/ft³ fuel loading density over one total burn cycle.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eEfficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eDelivered: Remotely provided to other rooms through ducting of min. 10 lb\/ft³ fuel loading density over one total burn cycle.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eEfficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.\u003c\/p\u003e\n\u003cp id=\"note-order-12\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e11\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (HHV).\u003c\/p\u003e\n\u003cp id=\"note-order-13\" class=\"p-head-price-small\"\u003e\u003csup\u003e(\u003cstrong\u003e12\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGENERAL FEATURES\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width and over depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Alcove\" data-order=\"41\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e731 lb (332 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 1\/2\" X 10 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Ventiloi\" data-order=\"51\"\u003e\n\u003ctd\u003eBlower (hp \/ speed \/ CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/3 \/ 1 \/ 875\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimFilti\" data-order=\"53\"\u003e\n\u003ctd\u003eFilter – dimensions (Width X Height X Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14\" X 25\" X 1\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e41 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e42 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 1\/8''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 3\/4''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21 1\/4''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TirCend\" data-order=\"78\"\u003e\n\u003ctd\u003eEasy-to-access ash drawer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PlenFrHi\" data-order=\"89\"\u003e\n\u003ctd\u003eAir return plenum – dimension (Depth or Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 3\/4''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PlenFrLi\" data-order=\"90\"\u003e\n\u003ctd\u003eAir return plenum – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 3\/4''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PlenChHi\" data-order=\"91\"\u003e\n\u003ctd\u003eHot air plenum – dimension (Depth or Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 5\/8''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PlenChLi\" data-order=\"92\"\u003e\n\u003ctd\u003eHot air plenum – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 1\/2''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 391\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B366.1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – ducts\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026lt;6'=6\" ; \u0026gt;6'=1\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026lt;6'=6\" ; \u0026gt;6'=1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e67\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – recommended for maintenance on option side\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – front\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e48\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – opposite side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection under the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e37 1\/8\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eManuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6368\/46261a_caddy_advanced.pdf\" class=\"pdf-list-link\"\u003e \u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e Caddy Advanced II Furnace Quick Start Guide\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.8 Mo)\u003c\/span\u003e \u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7858\/46424a_2025-11-04.pdf\" class=\"pdf-list-link\"\u003e \u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e Installation \u0026amp; operating instructions for Caddy Advanced II wood furnace\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 19.2 Mo)\u003c\/span\u003e \u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6445\/pf01020_advanced.pdf\" class=\"pdf-list-link\"\u003e \u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e Caddy Advanced II furnace dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7425\/certificat-tax-credit-caddy-2023-2032-rev2.pdf\" class=\"pdf-list-link\"\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6445\/pf01020_advanced.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"pdf-size\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7425\/certificat-tax-credit-caddy-2023-2032-rev2.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e Manufacturer's Certificate - USA Tax Credit\u003cbr\u003e(PDF - 0.1 Mo) \u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6403\/psg_quebec_city_program_2021.pdf\" class=\"pdf-list-link\"\u003e \u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e Manufacturer's Certificate - Quebec City Removal or Replacement Program \u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.2 Mo)\u003c\/span\u003e \u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":50774011838770,"sku":"PF01020","price":4977.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/6642\/4370\/files\/Screenshot2024-12-04175511.png?v=1767376767","url":"https:\/\/tristatefireplaces.com\/products\/osburn-caddy-advanced-wood-furnace-pf01020","provider":"Tri State Fireplaces","version":"1.0","type":"link"}